- Handy kits, specially designed for quality control of road markings with the entire range of measuring and test equipment for determination of wet film thickness, dry film thickness (only ZMK 5051-5053), temperature, relative humidity as well as the amount and embedding of drop-on-materials
- Comprehensive set of tools for self-monitoring or supervision of contractors
- Easy to handle
- Reliable and rapid results
Click here to request a quotation for this product. If possible, please indicate the desired version.
• 1 Zehntner folding rule
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
• 1 ZMM 5000 Digital Marking Gauge for measuring the dry film thickness of road markings (depending on version display in mm or changeable in inch)
• 1 ZND 2052 Wet Film Thickness Gauge, 100 µm to 950 µm, (3.9 mil to 37.4 mil) in steps of 25 µm (1 mil)
• 1 insertion thermometer, -10°C to +200°C (14°F to 392°F)
• 1 hygrometer, 25% to 95% relative humidity
• 1 electronic balance, 0 g to 2’000 g (0 lbs to 4.409 lbs)
• 1 magnifying glass, 6x magnification with scale
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
ZMK 5051 and 5051.inch Road Marking Control Kits for higher demands:
• 1 ZMM 5000 Digital Marking Gauge for measuring the dry film thickness of road markings (depending on version display in mm or changeable in inch)
• 1 ZND 2052 Wet Film Thickness Gauge, 100 µm to 950 µm, (3.9 mil to 37.4 mil) in steps of 25 µm (1 mil)
• 1 insertion thermometer, -10°C to +200°C (14°F to 392°F)
• 1 hygrometer, 25% to 95% relative humidity
• 1 electronic balance, 0 g to 2’000 g (0 lbs to 4.409 lbs)
• 1 magnifying glass, 6x magnification with scale
• 1 Zehntner folding rule
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
• 1 Marking-wedge Gauge for testing the dry film thickness of road markings (depending on version with scale in inch)
• 1 ZND 2052 Wet Film Thickness Gauge, 100 µm to 950 µm, (3.9 mil to 37.4 mil) in steps of 25 µm (1 mil)
• 1 insertion thermometer, -10°C to +200°C (14°F to 392°F)
• 1 hygrometer, 25% to 95% relative humidity
• 1 electronic balance, 0 g to 2’000 g (0 lbs to 4.409 lbs)
• 1 magnifying glass, 6x magnification with scale
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
ZMK 5052 and 5052.inch Road Marking Control Kit standard version:
• 1 Marking-wedge Gauge for testing the dry film thickness of road markings (depending on version with scale in inch)
• 1 ZND 2052 Wet Film Thickness Gauge, 100 µm to 950 µm, (3.9 mil to 37.4 mil) in steps of 25 µm (1 mil)
• 1 insertion thermometer, -10°C to +200°C (14°F to 392°F)
• 1 hygrometer, 25% to 95% relative humidity
• 1 electronic balance, 0 g to 2’000 g (0 lbs to 4.409 lbs)
• 1 magnifying glass, 6x magnification with scale
• 1 Zehntner folding rule
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
• 1 ZMM 5000 Digital Marking Gauge for measuring the dry film thickness of road markings (depending on version display in mm or changeable in inch)
• 1 Marking-wedge Gauge for testing the dry film thickness of road markings (depending on version with scale in inch)
• 1 ZND 2052 Wet Film Thickness Gauge, 100 µm to 950 µm, (3.9 mil to 37.4 mil) in steps of 25 µm (1 mil)
• 1 insertion thermometer, -10°C to +200°C (14°F to 392°F)
• 1 hygrometer, 25% to 95% relative humidity
• 1 electronic balance, 0 g to 2’000 g (0 lbs to 4.409 lbs)
• 1 magnifying glass, 6x magnification with scale
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
• with customer-specified contents
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
ZMK 5053 and 5053.inch Road Marking Control Kits fully equipped:
• 1 ZMM 5000 Digital Marking Gauge for measuring the dry film thickness of road markings (depending on version display in mm or changeable in inch)
• 1 Marking-wedge Gauge for testing the dry film thickness of road markings (depending on version with scale in inch)
• 1 ZND 2052 Wet Film Thickness Gauge, 100 µm to 950 µm, (3.9 mil to 37.4 mil) in steps of 25 µm (1 mil)
• 1 insertion thermometer, -10°C to +200°C (14°F to 392°F)
• 1 hygrometer, 25% to 95% relative humidity
• 1 electronic balance, 0 g to 2’000 g (0 lbs to 4.409 lbs)
• 1 magnifying glass, 6x magnification with scale
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
ZMK 5054 Road Marking Control Kit tailor-made version:
• with customer-specified contents
• 1 Zehntner folding rule
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
• 1 ZMM 5000 Digital Marking Gauge for measuring the dry film thickness of road markings (depending on version display in mm or changeable in inch)
• 1 hygrometer, 25% to 95% relative humidity
• 1 infrared thermometer with laser -50°C up to +500°C (-58°F up to 932°F)
• 1 electronic balance, 0 g to 2’000 g (0 lbs to 4.409 lbs)
• 1 magnifying glass, 6x magnification with scale
• 1 carrying case
ZMK 5051.T and 5051.T.inch Road Marking Control Kits for higher demands for thermoplastics:
• 1 ZMM 5000 Digital Marking Gauge for measuring the dry film thickness of road markings (depending on version display in mm or changeable in inch)
• 1 hygrometer, 25% to 95% relative humidity
• 1 infrared thermometer with laser -50°C up to +500°C (-58°F up to 932°F)
• 1 electronic balance, 0 g to 2’000 g (0 lbs to 4.409 lbs)
• 1 magnifying glass, 6x magnification with scale
• 1 Zehntner folding rule
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
• 1 Marking-wedge Gauge for testing the dry film thickness of road markings (depending on version with scale in inch)
• 1 hygrometer, 25% to 95% relative humidity
• 1 infrared thermometer with laser -50°C up to +500°C (-58°F up to 932°F)
• 1 electronic balance, 0 g to 2’000 g (0 lbs to 4.409 lbs)
• 1 magnifying glass, 6x magnification with scale
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
ZMK 5052.T and 5052.T.inch Road Marking Control Kit standard version for thermoplastic:
• 1 Marking-wedge Gauge for testing the dry film thickness of road markings (depending on version with scale in inch)
• 1 hygrometer, 25% to 95% relative humidity
• 1 infrared thermometer with laser -50°C up to +500°C (-58°F up to 932°F)
• 1 electronic balance, 0 g to 2’000 g (0 lbs to 4.409 lbs)
• 1 magnifying glass, 6x magnification with scale
• 1 Zehntner folding rule
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
• 1 ZMM 5000 Digital Marking Gauge for measuring the dry film thickness of road markings (depending on version display in mm or changeable in inch)
• 1 Marking-wedge Gauge for testing the dry film thickness of road markings (depending on version with scale in inch)
• 1 hygrometer, 25% to 95% relative humidity
• 1 infrared thermometer with laser -50°C up to +500°C (-58°F up to 932°F)
• 1 electronic balance, 0 g to 2’000 g (0 lbs to 4.409 lbs)
• 1 magnifying glass, 6x magnification with scale
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
ZMK 5053.T and 5053.T.inch Road Marking Control Kits fully equipped for thermoplastic:
• 1 ZMM 5000 Digital Marking Gauge for measuring the dry film thickness of road markings (depending on version display in mm or changeable in inch)
• 1 Marking-wedge Gauge for testing the dry film thickness of road markings (depending on version with scale in inch)
• 1 hygrometer, 25% to 95% relative humidity
• 1 infrared thermometer with laser -50°C up to +500°C (-58°F up to 932°F)
• 1 electronic balance, 0 g to 2’000 g (0 lbs to 4.409 lbs)
• 1 magnifying glass, 6x magnification with scale
• 1 Zehntner folding rule
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
• with customer-specified contents
• 1 certificate of manufacturer
• 1 instruction manual
• 1 carrying case
ZMK 5054 Road Marking Control Kit tailor-made version:
• with customer-specified contents